Live status · checked every 15 minutes
Is Google Cloud down right now?
Google Cloud Platform runs compute, storage, databases, networking and Vertex AI for businesses worldwide.
Live reader reports
Is Google Cloud down for you?
Tap what's not working, or tell us it works. Reports are anonymous, one per visitor.
No reports in the last 24 hours. Be the first to tell other readers what you're seeing.
Google Cloud not working for you?
- Check the region or product you use on the official status page: many incidents only hit one region.
- Test your site from another network, or with an online "check website" tool, to rule out your own connection.
- Read the exact error code in your logs: 5xx errors point to the provider, 4xx errors usually to your setup.
- Retry deployments and API calls with backoff instead of hammering the service.
Google Cloud outage history
Last 30 daysFixed Multiple services were experiencing issues in the europe-west2 region.
Affected: AlloyDB for PostgreSQL, Apigee, BigQuery Data Transfer Service, Cloud Data Fusion, Cloud Filestore, Cloud Firestore, Cloud Load Balancing, Cloud Memorystore, Cloud NAT, Cloud Run, Cloud Spanner, Cloud Workstations, Datastream, Google App Engine, Google BigQuery, Google Cloud Bigtable, Google Cloud D...
-
# Incident Report ## Summary On Monday, 19 Oct 2026 at 22:53 US/Pacific (Tuesday, 20 Oct 2026, 06:53 BST), a data center facility that hosts europe-west2-b, a zone within the europe-west2 cloud region, experienced an external electrical power disruption. This resulted in service unavailability for workloads located in this zone. The subsequent failover of these workloads to unaffected zones and alternate regions caused transient latency and elevated error rates across the broader europe-west2 region. The resolution of the main impact was completed within 6 hours and 8 minutes. ## Root Cause **Facility architecture and background:** The data center facility in the UK region hosts Cloud clusters serving the europe-west2-b zone, which form part of the multi-zonal europe-west2 Cloud region. The site relies on a 2N utility power architecture—where the facility has complete duplicate power paths for every critical load—backed by a central high-voltage generator bank managed by a dual-redundant Programmable Logic Controller (PLC). Primary utility power is supplied to the facility via two independent feeders (A and B), supplemented by a standby utility connection configured for manual campus-wide transfer during maintenance operations or emergency events. The two high-voltage primary feeders (A and B) terminate at separate primary intake switchboards capable of closed-loop operation if either board is taken offline. Switching between the primary and standby utility providers utilize…
-
## Incident Report ### **Summary** On Monday, 19 Oct 2026 (Tuesday, 20 Oct BST), a data center facility that hosts europe-west2-b, experienced an external electrical power disruption. This resulted in service unavailability for workloads located in this zone. As traffic was redirected to alternative cloud regions or unaffected zones within europe-west2 cloud region, these workloads experienced transient latency and elevated errors affecting services across europe-west2. The primary impact was mitigated after 6 hours 8 minutes. ### **Root Cause** **Facility architecture and background:** The data center facility in the UK region hosts Cloud clusters serving the europe-west2-b zone, which form part of the multi-zonal europe-west2 Cloud region. The site relies on a 2N utility power architecture—meaning the facility has complete duplicate power paths for every critical load—backed by a central high-voltage generator bank managed by a dual-redundant Programmable Logic Controller (PLC). Primary utility power is supplied to the facility via two independent feeders (A and B), supplemented by a standby utility connection configured for manual campus-wide transfer during maintenance operations or emergency events. The two high-voltage primary feeders terminate at separate primary intake switchboards capable of closed-loop operation if either board is taken offline. Switching between the primary and standby utility providers utilizes open transitions and key interlocks to prevent para…
-
## Preliminary Incident Report We recognize that Google Cloud services are critical to your organization, and we sincerely apologize for the disruption this incident may have caused to your business. We are working to address the root cause and prevent this from occurring in the future. Please note, this information is based on our best knowledge at the time of posting and is subject to change as our investigation continues. A final Incident Report with preventative actions will be posted once our investigation is complete. If you have experienced impact outside of what is listed below, please reach out to Google Cloud Support using [**https\://cloud.google.com/support**](https://cloud.google.com/support). ## Date/Time of the Issue Incident Start:19 Oct 2026 23:00 US/Pacific / 20 Oct 2026 07:00 BST Incident End: 20 Oct 2026 05:10 US/Pacific / 20 Oct 2026 13:10 BST Duration: 6 hours, 10 minutes ## Summary On Monday, 19 October 2026 (Tuesday, 20 October BST), multiple Google Cloud Platform services in the europe-west2 region experienced service disruptions, elevated error rates, Application Programming Interface (API) timeouts, and processing latency for a duration of 6 hours and 10 minutes. The disruption was triggered by an electrical power interruption at the datacenter facility hosting availability zone europe-west2-b, which temporarily took physical host servers, network routing hardware, and storage systems offline. This subsequently caused secondary failover and queuing…
-
**Summary** Multiple services were experiencing issues in the europe-west2 region. **Description** The issue with impacted GCP products has been mitigated for most of the customers and it is believed to be affecting currently a very small number of customers and our Engineering Team is working on it. If you have questions or are impacted, please open a case with the Support Team and we will work with you until this issue is resolved. No further updates will be provided here. We will publish an analysis of this incident once we have completed our internal investigation. We thank you for your patience while we're working on resolving the issue. **Symptoms** Google Cloud services were unavailable in europe-west2-b zone; some services in europe-west2 region might experienced elevated errors and intermittent network issues. **Workaround** None as the issue has been mitigated.
-
**Summary** Multiple services are experiencing issues in the europe-west2 region. **Description** We are seeing the recovery of services for most workloads in europe-west2 as of Tuesday, 2026-10-20 05:10 PDT. We will provide an update by Tuesday, 2026-10-20 07:00 PDT with current details. We apologize to all who are affected by the disruption. **Symptoms** Google Cloud services are unavailable in europe-west2-b zone; some services in europe-west2 region may experience elevated errors and intermittent network issues. **Workaround** If feasible, the impacted customer may try to migrate their workload impacted to another available location (zone or region).
-
**Summary** Multiple services are experiencing issues in the europe-west2 region. **Description** We are experiencing an issue with multiple services in europe-west2 beginning on Monday, 2026-10-19 23:08 PDT. A power event caused an outage within europe-west2-b zone. The power event is mitigated. We are seeing the recovery of services and are prioritizing the recovery of existing workloads.Customers may not be able to yet create new workloads. Full recovery of existing workloads should be completed, tentatively by Tuesday, 2026-10-20 06:00. We will provide an update by Tuesday, 2026-10-20 06:00 PDT with current details. We apologize to all who are affected by the disruption. **Symptoms** Google Cloud services are unavailable in europe-west2-b zone; some services in europe-west2 region may experience elevated errors and intermittent network issues. **Workaround** If feasible, the impacted customer may try to migrate their workload impacted to another available location (zone or region).
-
**Summary** Multiple services are experiencing issues in the europe-west2 region. **Description** We are experiencing an issue with multiple services in europe-west2 beginning on Monday, 2026-10-19 23:08 PDT. Due to a power event we had suffered an outage within europe-west2-b zone. The power event is mitigated. Partial mitigation to infrastructure services will be observed within the next 30 minutes and the remaining services will be mitigated there after. We will provide an update by Tuesday, 2026-10-20 05:00 PDT with current details. We apologize to all who are affected by the disruption. **Symptoms** Google Cloud services are unavailable in europe-west2-b zone; some services in europe-west2 region may experience elevated errors and intermittent network issues. **Workaround** If feasible, the impacted customer may try to migrate their workload impacted to another available location (zone or region).
-
**Summary** Multiple services are experiencing issues in the europe-west2 region. **Description** We are experiencing an issue with multiple services in europe-west2 beginning on Monday, 2026-10-19 23:08 PDT. Our engineering team continues to investigate the issue. We will provide an update by Tuesday, 2026-10-20 05:00 PDT with current details. We apologize to all who are affected by the disruption. **Symptoms** Multiple Google Cloud services are experiencing elevated errors and intermittent network failures in europe-west2 region. Note: Looker Studio is not impacted by this outage. **Workaround** If feasible, the impacted customer may try to migrate their workload impacted to another available location (zone or region).
-
**Summary** Multiple services are experiencing issues in the europe-west2 region. **Description** We are experiencing an issue with multiple services in europe-west2 beginning on Monday, 2026-10-19 23:08 PDT. Our engineering team continues to investigate the issue. We will provide an update by Tuesday, 2026-10-20 04:00 PDT with current details. We apologize to all who are affected by the disruption. **Symptoms** Multiple Google Cloud services are experiencing elevated errors and intermittent network failures in europe-west2 region. Note: Looker Studio is not impacted by this outage. **Workaround** If feasible, the impacted customer may try to migrate their workload impacted to another available location (zone or region).
-
**Summary** Multiple services are experiencing issues in the europe-west2 region. **Description** We are experiencing an issue with multiple services in europe-west2 beginning on Monday, 2026-10-19 23:08 PDT. Our engineering team continues to investigate the issue. We will provide an update by Tuesday, 2026-10-20 02:30 PDT with current details. We apologize to all who are affected by the disruption. **Symptoms** Multiple Google Cloud services are experiencing elevated errors and intermittent network failures in europe-west2 region. **Workaround** None for now
Frequently asked questions
Is Google Cloud down right now?
No. As of 18:45 UTC on 18 November 2026, Google Cloud is working normally. If it is not working for you, try the checklist on this page.
When was the last Google Cloud outage?
The last incident was "Multiple services were experiencing issues in the europe-west2 region." on 20 October 2026, fixed after 6 hours 8 minutes.
Why is Google Cloud not working for me?
If this page shows no problem and few readers report one, the cause is usually local: your connection, a VPN or firewall, an outdated app or a sign-in problem. Work through the checklist above, then report it here so other readers can see it.
Unofficial status page. Teczpert is not affiliated with Google Cloud. Status data comes from the official status page and is checked every 15 minutes; reports come from readers. Official source: status.cloud.google.com.